|
Research Reports Filter by Author11 report(s) found for Chris Pantelides In several states, bridge deck delamination of reinforced concrete bridge decks built with partial depth precast concrete panels and cast-in-place concrete has been observed. The partial depth precast concrete panels are typically prestressed. Recently, one such failure was observed in Utah. There is... A numerical model simulating the seismic behavior of precast concrete columns confined with glass fiber reinforced polymer (GFRP) spirals and longitudinally reinforced with steel or a combination of steel and GFRP bars was developed using the Open System for Earthquake Engineering Simulation (OpenSees).... Fiber reinforced polymer (FRP) composite materials have been studied and applied to reinforced concrete (RC) structures for strengthening or seismic retrofit for many years. This research is related to using FRP composites in new bridge structures. Capacity degradation in RC components of existing bridges... A new method for building seismically resilient bridges is proposed using accelerated bridge construction (ABC) methods. The hybrid two-column bridge bent consists of post-tensioned precast concrete columns with a buckling restrained brace (BRB) as an external energy dissipation device. The design of... The use of precast concrete in bridge construction has been abundant in recent years because of its efficiency and superior quality control. Precast components are connected at the bridge site to reduce construction time and traffic disturbance. The Grouted Splice Sleeve (GSS) connection provides good... Precast concrete construction has been proven to be very efficient in bridge engineering, especially in accelerated bridge construction (ABC), where precast concrete components are connected to save time and minimize disruption of traffic. Post-tensioned (PT) concrete structural elements, when combined... Reinforced concrete bridge wall piers constructed using older codes perform inadequately during strong earthquakes; deficiencies include short reinforcement lap splices, insufficient steel reinforcement ratios in the longitudinal and transverse direction, and inadequate seismic detailing. Three half-scale... This project studies effective configurations of self-centering devices in the seismic retrofit of curved bridges for control of longitudinal and lateral forces. Reparability of bridge columns is investigated experimentally. A seismic retrofit and repair technique using a Carbon Fiber Reinforced Polymer... Connections between precast concrete elements must be able to withstand significant stresses and deformations in earthquakes. The grouted splice sleeve (GSS) connector is being considered for connecting footing, column, and cap beam elements in accelerated bridge construction (ABC). There are limited... Grouted Splice Sleeve (GSS) connectors are being considered for connecting bridge columns, footings, and pier caps in Accelerated Bridge Construction (ABC). A repair technique for precast reinforced concrete bridge column-to-footing and column-to-pier cap joints constructed with GSS connectors has been...
|