Upper Great Plains Transportation Institute

Research Reports
Report Details

Title:
Validation of AlertMeter Fatigue Assessment Device
Authors:
University:
University of Denver
Publication Date:
Mar 2021
Report #:
MPC-21-432
Project #:
TRID #:
Keywords:
Type:
Research Report – MPC Publications

Abstract

The current study examined a new mobile app for the measurement of fatigue and alertness in the workplace, the AlertMeter. Seventeen participants experienced 36-hour sleep deprivation and were measured every two hours. Sixteen of the 17 participants were able to stay awake the entire study. No adverse events were observed or reported. The AlertMeter demonstrated strong validity as a measure of fatigue. It demonstrated significant concurrent validity with the psychomotor vigilance test and self-ratings of fatigue. The AlertMeter memory tests demonstrated inconsistent correlations with other measures of working memory. Overall, the AlertMeter is an effective and valid tool for detecting fatigue.

How to Cite

Owen, Jesse, and Patrick Sherry. Validation of AlertMeter Fatigue Assessment Device, MPC-21-432. North Dakota State University - Upper Great Plains Transportation Institute, Fargo: Mountain-Plains Consortium, 2021.